Customization: | Available |
---|---|
Warranty: | 1 Year |
Relative Humidity: | ≤ 85% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameter
|
|
|
Experimental voltage
|
AC100 ± 10V (test voltage for two samples)
|
|
The difference between the indicated temperature and the actual temperature is ≤ 2 ; Heating mold size 100x100x70mm, test temperature can be set at room temperature -500 , automatic constant temperature; Error of 120s in the timing device for heating the mold with a 90 "intersection angle of two lines+1s
|
|
|
Sensitivity (sample breakdown action current)
|
When the test passes a current of 5 ± 0.5mA, the instrument alarms
|
|
Test circuit short-circuit current
|
≤ 50mA
|
|
Timing device (sample preheating time)
|
0-9 minutes and 59 seconds, adjustable, with a timing error of ± 1 second
|
|
Test temperature
|
50~500 can be set, with automatic constant temperature; The temperature difference at the intersection of the
display and the test is less than 2 ' |
|
Heating power
|
1000W
|
|
Working environment temperature
|
0-40 , relative humidity ≤ 85%
|
|
Power supply voltage
|
AC220V ± 5%, 50Hz
|
|
External dimensions
|
LxWxH 540x310x345mm
|
|
Weight
|
32kg
|