Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Spec
|
Application
|
Test
|
200kV5kJ
|
Without a cutoff device, an oscilloscope, or a data acquisition card
|
6-10kV class switches and insulators; lightning impulse voltage full-wave test, waveform 1.2/50µs.
|
200kV10kJ
|
Without a cutoff device, an oscilloscope, or a data acquisition card
|
6-10kV class switches and insulators; transformers and instrument transformers requiring no chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs |
200kV10kJ
|
With cutoff device, Tektronix 1102 oscilloscope or data acquisition card
|
6-10kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
300kV7.5kJ
|
Without cutoff device, oscilloscope, or data acquisition card
|
10-35kV class switches and insulators; lightning impulse voltage full-wave test, waveform 1.2/50µs
|
300kV15kJ
|
Without cutoff device, Tektronix 1102 oscilloscope or data acquisition card
|
10-35kV class switches and insulators; transformers and instrument transformers requiring no chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs |
300kV15kJ
|
300kV single-stage cutoff device, oscilloscope, or data acquisition card
|
10-35kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
300kV30kJ
|
300kV single-stage cutoff device, Tektronix 2012 oscilloscope or data acquisition card
|
10-35kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
400kV10kJ
|
Without cutoff device, oscilloscope
|
10-35kV class switches and insulators; lightning impulse voltage full-wave test, waveform 1.2/50µs
|
400kV20kJ
|
400kV single-stage cutoff device, oscilloscope
|
10-35kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
400kV20kJ
|
Without cutoff device, oscilloscope, or data acquisition card
|
10-35kV class switches and insulators; transformers and instrument transformers requiring no chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs |
400kV30kJ
|
300kV single-stage cutoff device, oscilloscope
|
10-35kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
400kV40kJ
|
Without cutoff device, oscilloscope, or data acquisition card
|
10-35kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
600kV15kJ
|
600kV single-stage steepening device, data acquisition card
|
10-35kV class switches; insulators requiring steep wave test; lightning impulse voltage full-wave test, waveform 1.2/50µs; steep
wave |
600kV30kJ
|
400kV single-stage cutoff device, oscilloscope
|
10-66kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
500kV30kJ
|
Single-stage cutoff device, oscilloscope
|
|
800kV20kJ
|
|
10-110kV class switches and insulators; transformers and instrument transformers requiring no chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs |
800kV40kJ
|
Without cutoff device, oscilloscope
|
10-110kV class switches and insulators; transformers and instrument transformers requiring no chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs |
800kV40kJ
|
800kV cutoff device, oscilloscope
|
10-110kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
800kV80kJ
|
800kV cutoff device, oscilloscope
|
10-110kV class switches and insulators; transformers and instrument transformers requiring chopped-wave test; lightning impulse
voltage full-wave test, waveform 1.2/50µs; chopped wave 2-6µs |
Performance parameters of complete equipment
|
0.1A
|
|
The main technical parameters of the test platform are:
|
0.001a
|
|
Input power
|
AC220V/3kVA, 50Hz/60Hz
|
|
DC maximum charging voltage
|
DC22kV, maximum charging current 0.1A
|
|
Charging time
|
22kV40s~60s
|
|
Charging voltage setting
|
test initialization to pre-set and set charging voltage
|
|
Residual voltage level
|
≤2.5kV
|
|
Automatic polarity conversion
|
50Hz±1
|
|
the number of positive and negative polarity impacts can be set separately. Phase automatic tracking, 0-359° adjustable Action load power AC5-500V/5A, built-in decoupling capacitor, inductor. Manual boost, buck, meter display. Combination wave impulse generator circuit
|
|
|
Capacitance
|
8uF Charging voltage 25kV
|
|
Output capacity
|
10%~110%, reverse peak20% (without decoupling load)
|
|
Open circuit voltage waveform
|
T1:1.2±30%, T2:50±10%
|
|
Short circuit current waveform
|
T1:8±10%, T2:20±10% (without decoupling load)
|
|
Short circuit current waveform
|
T1:8±20%, T2:20±20% (with decoupling load)
|
|
Output impedance
|
2 ohms±10%
|
|
Test cabinet
|
400*400*300mm (customized according to customer requirements)
|
|
Cabinet size
|
600*800*1800mm
|
|
Weight
|
about 600 kg
|
|
The cabinet is equipped with movable casters and fixed supports, which can be easily moved and positioned;
|
|
Applicable conditions
|
|
|
|
|
||||
Altitude
|
|
1000m
|
|
|
||||
Ambient temperature
|
|
-540, maximum daily
|
|
|
||||
temperature difference
|
|
25
|
|
|
||||
Relative humidity
|
|
85% (20), no condensation
|
|
|
||||
Usage environment
|
|
indoors
|
|
|
||||
No conductive dust, no fire and explosion hazards, no corrosive metal and insulating gas
|
|
|
|
|
||||
The waveform of the power supply voltage is a sine wave, the waveform distortion rate is < 5%, and the voltage fluctuation is lessthan 10%
|
|
|
|
|
||||
The grounding resistance is not more than 0.5Ω
|
|
|
|
|