Kdgk-703s Portable Integrated Calibrator (millivolt generator)

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Still deciding? Get samples of US$ 2316/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (25)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
  • Kdgk-703s Portable Integrated Calibrator (millivolt generator)
Find Similar Products

Basic Info.

Withstand Voltage
100kv
Power
250W
Customized Support
OEM, ODM, Obm, Software Reengineering
Partial Discharge
80kv
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000

Product Description


Kdgk-703s Portable Integrated Calibrator (millivolt generator)
KDGK-703S portable integrated calibrator (millivolt generator) Instruction Manual
 
KDGK-703S portable integrated calibrator (millivolt generator) is a high-precision, high-resolution and multipurpose automatic instrument calibration instrument that integrates digital display voltage, current, frequency standard signal source, Pt100 platinum resistance temperature analog standard signal source, digital voltage, current, and frequency measurement functions.
It has signal output and test functions, and can verify the following types of instruments:
Sensor, transmitter, regulator, recorder, intelligent flow totalizer, electric/pneumatic actuator and other conventional industries
Automation instrument. It can also be used to calibrate and adjust a series of computer interface boards, such as resistance boards, A/D boards
D/A board, etc. It can be widely used in petroleum, chemical industry, smelting, paper making, power generation, subway rail transit and instrumentation
Industry and scientific research departments.
Its technical performance conforms to the calibration standards of electrical II and III automatic instruments, and its working environment conforms to
Relevant provisions of two groups of instruments in GB6587.1-86 "General Outline for Environmental Testing of Electronic Measuring Instruments".
Compared with similar instruments at home and abroad, it has the following four characteristics:
·It has a full range of functions, including almost all electrical signals of automatic instruments; High precision, small size, light weight,
In particular, it can be directly applied to the field to implement on-site adjustment and maintenance of various industrial process control automation instruments.
·It can output three active milliampere signals at the same time, greatly reducing the need for multiple input signal instruments (such as intelligent flow
Calibration and maintenance of totalizer, elbow flowmeter, etc.).
·It has a wide range of AC working voltage range (180~260V. AC), and can adapt to harsh work in industrial sites
environment
·The instrument can work in the measurement and output state at the same time. There are two four-half LED displays, and each display has
Four unit display lamps display mA, mV, V and KHz respectively. The output value and
Its units and measured values and their units
 
Product features
1. Output function:
1. There is a continuous adjustable working power supply of 0~25.00V.DC that can be used as a two-wire transmitter, and a DC voltage signal of 0~199.99mV.DC that can be used as the analog output signal of various thermocouples.
2. It has two Pt100 thermal resistance simulators, which can output Pt100 platinum resistance - 50 ºC, - 20 ºC
-3ºC,-8ºC,0ºC,7ºC,11ºC,50ºC,100ºC,150ºC,160ºC,170ºC,190ºC,
Analog resistance signals of 200 ºC, 250 ºC and 300 ºC can be used as input signals of temperature transmitter (this function is newly added as required by some customers, and the deviation of index parameters is only for reference).
3. There are three channels of active current output: two channels of 0~22.00mA.DC and one channel of 0~19.999mA.DC. It can be used as input or output signal of type II and III instruments, and can simulate type II and III transmitters during field calibration.
4. There is a channel of 10Hz ~ 1.9999kHz frequency signal output, which can be used as the input signal of the secondary instrument of vortex flowmeter and turbine flowmeter.
 
2. Measurement function:
1. It can measure the voltage signal of 0~40V.DC;
2. It can measure the voltage signal of 0~199.99mV.DC;
3. The current signal of 0~100.00mA.DC can be measured;
4. It can measure the TTL level frequency signal of 5Hz~1.9999kHz and the frequency signal of vortex flowmeter and turbine flowmeter.

3, Technical indicators
1. DC voltage output
Output range accuracy resolution
0 ~ 25.00V ± (0.1% reading+5 words) 10mV
0 ~ 199.99mV ± (0.05% reading+10 words) 10uV
Note: The DC voltage source of the instrument outputs 0~25.00V.DC, 40mA, please do not operate with short circuit or overload, otherwise the overload will burn out this function of the instrument.
2. DC current output
Output range accuracy resolution
0 ~ 22.00mA (I circuit) ± (0.05% reading+5 words) 10uA
0 ~ 22.00mA (II circuit) ± (0.05% reading+5 words) 10uA
0 ~ 19.999mA (III circuit) ± (0.05% reading+10 words) 1uA
Note: The last three red keys in the bottom row of the instrument are normally pressed, so that the mA value of the last output current signal will always be maintained. MA output needs to be connected with load or short circuit to form a loop. It is to clip the black and red alligator clips of the output line together, and then press the corresponding knob to adjust to the required milliampere value.
3. Output frequency
Range accuracy resolution
10Hz ~ 1.9999kHz ± (0.1% reading+10 words) 1Hz
4. Thermal resistance analog output
Thermal resistance type Range range Output accuracy
Pt100 -50~400ºC ±0.1%
5. DC voltage measurement
Range range accuracy resolution internal resistance
0 ~ 40V ± (0.1% reading+5 words) 0.01V>10MW
0 ~ 199.99mV ± (0.05% reading+5 words) 10uV>10MW
6. DC current measurement
Range range accuracy resolution internal resistance
0 ~ 100.00mA ± (0.05% reading+5 words) 10uA 10W
7. Frequency measurement
Range range accuracy resolution internal resistance
10 ~ 1.9999kHz ± (0.1% reading+10 words) 1Hz>10MW
8. Power supply: AC 220 V ± 20% (50Hz ± 2);
9. Operating environment: temperature range: - 10 ºC~+50 ºC; Relative humidity:+40 ºC 80% RH;
10. Power consumption: 4W (MAX);
11. Calibration period: one year;
12. Overall dimension: 300 × one hundred and forty × 340 mm (width × high × Deep);
13. Weight: about 2Kg.
 
Instructions for use
Before use, please be familiar with the functions of switches, knobs, terminals, sockets, etc. on the front and rear panels of the instrument. because
This instrument has many functions, and may use many functions of this instrument at the same time during use. Please read carefully
This manual is to be familiar with various functions of the instrument, so as not to cause unnecessary trouble to your work.
Figure 1 Schematic diagram of front panel
2 - Frequency measurement display key (Ftest) 3 - Voltage measurement display key (Vtest)
4-millivolt measurement display key (mVtest) 5-milliampere measurement display key (mAtest)
6 - Frequency output display key (Fout) 7 - Voltage output display key (Vout)
8-channel mA output display key (mAI) 9-channel mA output display key (mAII)
10-III channel milliampere and millivolt output display key (mAIII)
11-III channel milliampere and millivolt output switch key (mAIII/mV), this key is black. When millivolt output is pressed, press the left third channel current output key at the same time to switch to millivolt output, and press the black key when the third channel milliampere output is pressed
12-I-channel milliampere output switch key (IEXT/INT) 13-II-channel milliampere output switch key (IIEXT/INT)
14-channel III mA output switch key (IIIEXT/INT) 15, 17-channel II current output port (mAIIout)
16. 18-III current output port (mAIIIout) 19, 21-millivolt voltage output port (mVout)
20. 22-circuit I current output port (mAIout) 23-circuit III current coarse adjustment knob
24-circuit III current fine adjustment knob 25-circuit II current fine adjustment knob
26-Circuit II current coarse adjustment knob 27-Circuit I current fine adjustment knob
28 - I-circuit current coarse adjustment knob 29 - voltage output fine adjustment knob (Vout)
30 - Voltage output coarse adjustment knob (Vout) 31 - Frequency output fine adjustment knob (Fout)
32 - Frequency output coarse adjustment knob (Fout) 33 - Pt100 output knob
34 - Output unit indicator 35 - Measurement unit indicator
36 - Output 4 1/2 LED display 37 - Measure 4 1/2 LED display
 
Front panel function description:
☆ Three-channel current output and millivolt output are output through the front panel jack. Each output signal is corresponding to two sockets. The red socket is the signal "+", and the black socket is the signal "-"; When three circuits of current are output, the signal line needs to be short-circuited or connected to the load.
☆ Display selection. The instrument can display ten values: four measured values and six output values (including three active current outputs, one millivolt output, one frequency output and one "0~25.00V" voltage output). There are nine display selection keys (No. 2-10) in the instrument. The measured value or instrument output value can be switched to the display by pressing the corresponding key for the user to read. The output value and the measured value are independent of each other.
☆ The output signal size is adjusted by the corresponding adjustment knob (No. 23-32) (see Figure 1).
☆ When the measured signal or output signal of the instrument exceeds the range, the LED display flashes.
Rear panel function description:

Figure 2 Schematic diagram of rear panel
1. - Voltage measuring port (Vtest+) 2. - Voltage measuring port (Vtest -)
3. - frequency measurement port (Ftest+) 4. - frequency measurement port (Ftest -)
5. - millivolt voltage measuring port (mVtest+) 6. - millivolt voltage measuring port (mVtest -)
7. - mA current measuring port (mAtest+) 8. - mA current measuring port (mAtest -)
9. - Voltage output port (Vout+) 10, - Voltage output port (Vout -)
11. - Frequency output port (Fout+) 12. - Frequency output port (Fout -)
13. - Fan port 14, - AC voltage input port
15. - AC switch (OFF AC ON)
16. 17. - Pt100-II output port 18, 19. - Pt100-I output port
 
Instructions for each function of the instrument:
The various functions of the instrument are mainly designed for industrial automation instruments. It is different from the universal multimeter. It can be said that the instrument is the multimeter and signal source of industrial automation.
☆ Frequency measurement function: frequency measurement is designed according to the characteristics of frequency signals of current automatic instruments (turbine, vortex flowmeter, etc.). During measurement, connect the positive end of the measured frequency signal from the Ftest+jack on the rear panel, and connect the Ftest - jack to the negative end of the frequency. Press the Ftest key on the front panel, and the frequency value can be observed in the LED display window.
☆ Frequency output function: the frequency output by the instrument is the standard TTL level square wave signal. After the instrument is powered on, the frequency is output from the rear panel, the positive end of the output frequency of the Fout+jack, and the negative end of the output frequency of the Fout -. Press the Fout key on the front panel, and the output frequency value can be observed in the LED display window. Adjust the coarse and fine adjustment knobs of the frequency output on the front panel to adjust the output frequency value.
☆ Voltage measurement function: the DC voltage measurement function of the instrument is designed as (0~40V. DC), which can be used to measure the 24V. DC power supply voltage, 1~5V. DC, 0~10V. DC voltage signal of the field III instrument. During the measurement, connect the positive end of the measured voltage from the Vtest+jack on the rear panel, and connect the Vtest - jack on the rear panel to the negative end of the voltage. Press the Vtest key on the front panel, and the voltage value can be observed in the LED display window.
☆ DC voltage output function: instrument DC voltage source (0~25.0V.DC, 40mA, please do not operate with short circuit or overload, otherwise the overload will burn the instrument this function): after the instrument is powered on, the DC voltage source is output from the rear panel, the positive end of the output voltage of the Vout+jack, the negative end of the output voltage of the Vout - jack, press the Vout key on the front panel, the voltage output value can be observed in the LED display window, and the coarse adjustment of the front panel voltage output can be adjusted Adjust the knob to adjust the output voltage.
☆ Millivolt output function: Millivolt output is output from the front panel jack (the output mode is selected by the front mAIII/mV key, not pressing this key is mA output mode, pressing this key is mV output mode); Press the mAIII/mV key and IIIEXT/INT key. At this time, the mVout output jack on the front panel has a millivolt signal. Adjust the coarse and fine adjustment knob of the third current output on the front panel to obtain the required millivolt value. Press the mAIII key, and then the LED displays the output millivolt value.
☆ Millivolt measurement function: during measurement, the mVtest on the rear panel is connected to the positive end of the measured millivolt signal, and the mVtest on the rear panel is connected to the negative end of the measured millivolt signal. Press the mVtest key on the front panel, and the measured millivolt value can be observed in the LED window.
☆ mA output function: the instrument has three independent constant current circuits, which are selected by the IEXT/INT, IIEXT/INT and IIIEXT/INT keys on the front panel. Press the key, and the circuit current will work. The current is output from the jack on the front panel. Take the first current output as an example to illustrate the working process of the instrument. Connect the load to the current output jack mAIout of the front panel with the connecting wire, and power the instrument. Press IEXT/INT, press mAI key (the first current output display), and adjust the first coarse and fine adjustment knob to get the current output value you need.
☆ Thermal resistance simulation function: This function is equivalent to a resistance box. We select the precision resistance with accuracy of 2/10000 according to the dividing resistance value of Pt100. The user only needs to select the knob on the front panel to the corresponding temperature gear, and the corresponding resistance value can be output at the wiring terminal on the rear panel.
 
Application examples
This instrument is a multi-functional comprehensive calibration instrument, and the combination of instruments on site is also diverse. Therefore, we cannot explain the calibration of various instruments on site one by one. The following is just to illustrate the use of the multi-function combination of this instrument with the wiring of several representative instruments as an example.
1. Temperature transmitter:
For the calibration of type III two-wire thermal resistance temperature transmitter, if the instrument provides+24V working voltage, first press the Vout key to adjust the output power voltage to+24V, and then connect according to Figure 5, and select the current measurement m by the display key
 
Kdgk-703s Portable Integrated Calibrator (millivolt generator)
Kdgk-703s Portable Integrated Calibrator (millivolt generator)
Kdgk-703s Portable Integrated Calibrator (millivolt generator)
Kdgk-703s Portable Integrated Calibrator (millivolt generator)

Kdgk-703s Portable Integrated Calibrator (millivolt generator)Kdgk-703s Portable Integrated Calibrator (millivolt generator)Kdgk-703s Portable Integrated Calibrator (millivolt generator)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier