Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
  • Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Find Similar Products

Basic Info.

Model NO.
KDKC-2020
Time Measurement Range
1ms~300ms
Customized Support
OEM, ODM, Obm, Software Reengineering
Maximum Voltage of The Port
24V
Time Resolution
0.1ms
Three Independent Testing Power Sources
3A/1A Level; 0.6A/0.2A Gear
Resistance Measurement Range
0.3-40 Ω
Instrument Setting Sampling Rate
10-30kHz
Resistance Resolution
0.1 Ω
Transition Resistance Range
100 Ω
Accuracy: Transition Resistance
± 5% Reading ± 0.1 Ω
Power
Electronic
Transport Package
Wooden Box with Foam Inside
Trademark
KDZD
Origin
Hebei, China
HS Code
9030332000

Product Description


Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer

Products introduction
 
The KDKC-2020 transformer on load tap changer tester adopts computer control. Through a specially designed measurement circuit, it can measure the transition time, transition waveform, transition resistance, three-phase synchronicity, and other parameters of the on load tap changer. Users can directly measure them through the tap changer lead according to their needs and on-site conditions, or directly connect them through the transformer's three-phase bushing and neutral point.
 
The KDKC-2020 transformer on load tap changer tester has functions such as displaying, analyzing, storing, and printing the measured data. Solved the problem of outdated measurement methods and lack of specialized testing methods for on load tap changers in current power transformers. It is of great significance to timely diagnose potential faults of on load tap changer during preventive testing of power equipment and transformer overhaul, in order to improve the reliability of power system operation.
 
Technical parameter
Three independent testing power sources
3A/1A level; 0.6A/0.2A gear
Maximum voltage of the port
24V
Instrument setting sampling rate
10-30KHz
Resistance measurement range
0.3-40 Ω
Voltage mode
1A gear: 0.4 Ω~20 Ω 0.2A gear: 10 Ω~100 Ω
Transition resistance range
100 Ω
Resistance resolution
 0.1 Ω
Accuracy: Transition resistance
± 5% Reading ± 0.1 Ω
Time measurement range
1ms~300ms
Time resolution
0.1ms
Time measurement accuracy
 1ms~100ms ± 0.1ms; 100ms to 300ms ± 1%
Accuracy
Transition time: ± 0.5% Reading ± 0.2mS
Three phase synchronization
0.1ms; Sampling frequency: 10-20KHz
Processing section
High speed 32-bit microprocessor, storing up to 1000 sets of waveforms
High speed A/D converter
up to 400KHZ sampling rate
Power supply
AC220V10%; Power 180W
Size
420mm * 350mm * 220mm
Weight
 12kg
 
Product features
 
1. Test Y0, Y, and △ type transformers, and display the resistance values directly without conversion.
 
2. Humanized data analysis can automatically identify faults in the middle of the waveform and mark them.
 
3. The waveform display automatically adjusts the resistance and time amplitude based on the sampled data.
 
4. It can be tested with or without windings.
 
5. The four terminal wiring method provides high-precision resistance measurement without the need for wire compensation.
 
6. Continuous testing can be conducted during testing to save time on transformer power outages.
 
7. This transformer on load switch tester can generate Word reports, facilitating data management and querying.
 
8. The instrument is controlled by a small computer with an external configuration of 800 × 480 color LCD touch screen.
 
9. High speed printer, supporting external mouse, easy to operate.
 
10. The instrument can automatically save 1000 sets of data internally, or it can be saved on an external USB drive.
 
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer
Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer

Transformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer AnalyzerTransformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer AnalyzerTransformer Oltc on-Load Voltage Adjustment Switch Characteristics Tester on Load Tap Changer Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier