Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
  • Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Find Similar Products

Basic Info.

Model NO.
KDJB-903D
Frequency Range
0-1000Hz, Accuracy 0.01Hz
Phase
0-360 °, Accuracy 0.1 °
Harmonic Frequency
2-20 Times
Line Voltage Output (Effective Value)
0-240V
Time Range
1ms -9999s
Line Voltage Output Amplitude
0- ± 320V
Customized Support
OEM, ODM, Obm, Software Reengineering
Contact
0-250V DC
Switching Input Terminals
8 Pairs
DC Current Output
0- ± 5A/Phase, Accuracy: 0.2% ± 5mA
Power
Electronic
Phase Voltage/Line Voltage Output Power
40va/60va
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000
Production Capacity
5000

Product Description

 
 

Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Technical parameter
 
AC power source
Single phase current output (effective value): 0-10A/phase, accuracy: 0.1% ± 5mA
Three phase parallel output (effective value): 0-30A/Three phase same phase parallel output
Long term allowable working value (effective value) of phase current: 5A
Maximum output power per phase: 100VA
Maximum output power of three-phase parallel current: 300VA
Maximum allowable working time for triple current output: 5s
Frequency range: 0-1000Hz, accuracy 0.01Hz
Harmonic frequency: 2-20 times
Phase: 0-360 °, accuracy 0.1 °
 
DC current source
DC current output: 0- ± 5A/phase, accuracy: 0.2% ± 5mA
 
AC voltage source
Single phase voltage output (effective value): 0-120V/phase, accuracy: 0.1% ± 5mV
Line voltage output (effective value): 0-240V
Phase voltage/line voltage output power: 40VA/60VA
Frequency range: 0-1000Hz, accuracy: 0.01Hz
Harmonic frequency: 2-20 times
Phase: 0-360 °, accuracy: 0.1 °
 
DC voltage source
Single phase voltage output amplitude: 0- ± 160V, accuracy: 0.2% ± 5mV
Line voltage output amplitude: 0- ± 320V
Phase voltage/line voltage output power: 40VA/60VA
 
Switching terminal
Switching input terminals: 8 pairs
Empty contact: 1-20mA, 24V internal active output of the device
Potential flipping: passive contact: low resistance short circuit signal; Active contact: 0-250V DC
Switching output terminals: 4 pairs, air contact, breaking capacity: 110V/2A, 220V/1A
 
Other
Time range: 1ms -9999s, measurement accuracy: 1ms
Single unit volume weight: Volume 315 x 225 x 155 mm3, approximately 8.5Kg
Adapter power supply: charger 24V/2A
 
Working time of AC current
 
10A ≥ working current: working time>6 hours
 

Main features
 
1. Meet the requirements of on-site testing. This instrument has standard four phase voltage and three-phase current output, which can be used to test various traditional relays and protection devices, as well as modern microcomputer protection. Especially for transformer differential protection and backup automatic switching devices, the testing is more convenient.
 
2. Meet the national standard GB/T 7261-2016 "Basic Test Methods for Relay Protection and Safety Automatic Devices" and the standard DL/T 624-2010 "Technical Conditions for Microcomputer-based Test Devices for Relay Protection".
 
3. Windows XP operating interface, user-friendly human-machine interface, easy and fast operation; The embedded industrial control computer and 10.4-inch LED true color display screen with a resolution of 800 × 600 can provide rich and intuitive information, including the current working status of the device and various help information.
 
4. The local Windows XP system comes with a recovery function to avoid system crashes caused by illegal shutdowns or accidental operations.
 
5. Equipped with ultra-thin multifunctional quick connect buttons and an optical mouse, it can complete various operations through the keyboard or mouse like operating a regular PC.
 
6. The main control board adopts a DSP+FPGA structure, with 16 bit DAC output. It can generate high-density sine waves of 2000 points per week for the fundamental wave, greatly improving the quality of the waveform and enhancing the accuracy of the testing instrument.
 
7. The power amplifier adopts a high fidelity linear power amplifier, which ensures both the accuracy of small currents and the stability of large currents.
 
8. It uses a USB interface to communicate directly with the PC without the need for an adapter, making it convenient to use.
 
9. Can be connected to a laptop (optional) for operation. Laptops and industrial computers use the same set of software, without the need to relearn operating methods.
 
10. Equipped with GPS synchronization test function. The device can be equipped with a built-in GPS synchronization card (optional) that is connected to a PC through an RS232 port, enabling two testers to perform synchronous switching tests in different locations.
 
11. Equipped with an independent dedicated DC auxiliary voltage source output, with output voltages of 110V (1A) and 220V (0.6A) respectively. To be used for relays or protective devices that require DC working power supply.
 
12. It has software self calibration function, avoiding the need to open the chassis and adjust the potentiometer to calibrate accuracy, thereby improving the stability of accuracy.
 
 
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
 


Kdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test UnitKdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test UnitKdjb-903D Three Phase Microcomputer Relay Protection Tester System/Comprehensive Secondary Current Injection Relay Test Unit
 
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier