Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
  • Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
KDZD
Testing Voltage
0~430V
Input Power Supply
Hree-Phase AC 380V ±
Voltage Accuracy
≤ 1.0% ± 1 Word (F.S)
Input Current
7.5-250A
Rated Capacity
1.5-100kVA
Accuracy Class
≤ 1.0% ± 1 Word (F.S)
Rated Output Voltage
0-430V
Timing Length
0-9999s
Low Voltage Side Voltage
400V
Current Accuracy
≤ 1.0% ± 1 Word (F.S)
Measuring Range
1.5~100kVA
Low Voltage Side Current
7.5-250A
Rated Output Current
7.5~232.5A
Transport Package
Export Specific Standard Box
Trademark
KDZD
Origin
Hebei, China
HS Code
9030332000
Production Capacity
1500 Pieces

Product Description

Product Description
 
Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester

Product Features

1. Equipped with high-voltage voltage, low-voltage current, zero position indication, power indication, work indication, and timing indication;

2. Equipped with overcurrent protection, zero start protection, sound and light language alarm reminder

3. Adopting a new type of time relay, with a wider timing range (1S~99H)

4. Adopting a new type of current relay, it is more precise and reliable, ensuring personal and equipment safety.

5. Adopting a combination of hardware and software anti-interference technology, with stable performance and strong anti-interference ability

6. The high-voltage coil of the test transformer is a cylindrical multi-layer tower type, wound with high-quality polyester enameled wire and high voltage insulation material.

7. It has the characteristics of light weight, small size, convenient movement, and superior performance.

8. The test transformer (above 5kVA) is equipped with movable iron wheels.

9. This product is small in size and light in weight (20% -65% lighter than oil immersed test transformers of the same grade)

10. Clean, no oil stains, no maintenance required;

11. Not affected by adverse weather conditions, on-site transportation does not require static testing;

12. The insulation strength is significantly higher than that of oil immersed test transformers, with minimal corona;

13. It can be used for AC withstand voltage testing of electrical primary equipment under specified voltage, to assess the insulation strength of the tested object, and to discover insulation defects of the tested object.

Technical parameter

 Operation console


Rated capacity: 1.5-100kVA

Rated output current: 7.5~232.5A

Rated output voltage: 0-430V

Input power supply: three-phase AC 380V ± 10% (single-phase AC 220V ± 10%); 50Hz ± 5 Hz

Input current: 7.5-250A

Timing length: 0-9999S (special mode can be used for long-term work)

Voltage accuracy: ≤ 1.0% ± 1 word (F.S)

Current accuracy: ≤ 1.0% ± 1 word (F.S)

Note: If there are special parameter requirements, design and production can be carried out according to the user's technical parameters.


SF6 inflatable test transformer

Rated capacity: 1.5-100kVA

Low voltage side voltage: 400V

Low voltage side current: 7.5-250A

High voltage side AC output voltage: 0-300kV

High voltage side AC output current: 0-3000mA

Measurement ratio: 1000:1

Impedance voltage: 4-9%

Output voltage waveform: sine wave

Transformation ratio error: <± 1%

Waveform distortion rate: not more than 3%

Permissible continuous full load working time: ≥ 1-2 hours (temperature rise of 50 ºC)

No load loss: 0.2%~0.4.0%

Voltage measurement accuracy: 1.0% FS ± 3 words

Current measurement accuracy: 1.0% FS ± 3 words

SF6 insulation gas content: 99.999% (national standard)

Gas pressure: 0.4Mpa

The parameters of the AC DC dual purpose test transformer are as shown in the table above. The rated DC voltage in the DC parameters is 1.4 times the AC voltage, and the rated DC current is 0.7 times the AC current.
 
Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester
 
 

Electric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot TesterElectric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot TesterElectric Transformer Withstand High Voltage Transformer Testing 100kv AC/DC Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier