Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
  • Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
Find Similar Products

Basic Info.

Model NO.
CTP-120P
Output
0~100vrms,12arms,36A(Peak Value)
Dimensions
340 mm *300 mm *150mm
Application
CT PT Testing
Power
Electronic
Customized Support
OEM, ODM, Obm
Name
CT PT Tester
Trademark
kdzd
Origin
Hubei, China
HS Code
9030332000
Production Capacity
5000

Product Description


Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
Technical characteristics

Based on the frequency conversion method to test the volt ampere characteristic curve of CT, the maximum output is only 180V AC voltage and 12A AC current, but it can withstand CT testing with a turning point of up to 30kV.

Meet the steady-state or transient characteristic tests of excitation, transformation ratio, phase, polarity, secondary winding resistance, load, ratio difference, and angle difference for various types of CT (including high inflection point, large transformation ratio, and transformer bushing CT).

CT can be tested and analyzed in accordance with standards such as GB20840, GB1208 (IEC60044-1), and GB16847 (IEC60044-6),automatically providing parameters such as inflection point voltage/current, 10% error curve, 5% error curve, accuracy limit factor (ALF), instrument safety factor (FS), secondary time constant (Ts), residual magnetic coefficient (Kr), accuracy level,saturated and unsaturated inductance.

With just one test, the angle difference and specific difference of CT under 1%~120% rated current and different loads can be obtained, and the test results can also be extended to other current ranges and loads.

Can test the actual load and power factor of the transformer.

Can complete the excitation test, transformer ratio test, and polarity check of electromagnetic PT.

The interface is user-friendly and beautiful, with a Chinese graphical interface and a 5.7-inch transparent LCD display. It can be viewed under sunlight.

Using a rotating mouse operation, the operation is simple, fast, convenient, and easy to master.

The device can store 1000 sets of test data without losing power. It can be exported in real-time through a USB flash drive, and historical data can also be retrieved for analysis and comparison.

Provide upper computer software as a gift, generate Word format test reports, and achieve functions such as variable parameter analysis, cursor reading, and curve comparison.

The device is lightweight and portable, with a built-in printer on the panel that can automatically print generated test reports.
 
 
Output voltage
0~180v (RMS)
Output current
0~12a (RMS), peak value 36a
Voltage measurement accuracy
accuracy: ± 0.1%
Current measurement accuracy
accuracy: ± 0.1%
CT transformation ratio measurement range
1~30000; Accuracy:± 0.2%
PT transformation ratio measurement range
1~10000; Accuracy: ± 0.2%
Phase measurement
accuracy: ± 5 ', resolution: 0.5'
Measurement range of secondary winding resistance
0.1~300 Ω resolution: 0.2m Ω accuracy: 0.2% ± 2 m Ω
AC load measurement
0~300va resolution: 0.02va accuracy: 0.2% ± 0.2 VA
Input power voltage
AC220V ± 20%, 50Hz
Working conditions
temperature: -10 ºC ~50 ºC, humidity: ≤ 90%
Size
330mm × 310mm × 170mm
Weight
<9kg

Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function
Secondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking FunctionSecondary Current Injection Six Phase Relay Protection Test Box with Fault Self Diagnosis and Locking Function

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier