| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 1 Year |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Control Box | |
| Rated Capacity | 1.5~100kVA |
| Rated Output Current | 7.5~232.5A |
| Rated Output Voltage | 0~430V |
| Input Power | Three-phase AC 380V±10% (Single-phase AC 220V±10%); 50Hz±5 Hz |
| Input Current | 7.5~250A |
| Timing Length | 0~9999S (Special mode for extended operation) |
| Boost Speed Optional | 0.5kV/S~5kV/S (Manual or automatic control available) |
| Voltage Accuracy | ≤1.0%±1 digit (F.S) |
| Current Accuracy | ≤1.0%±1 digit (F.S) |
| Epoxy Resin Dry-Type Test Transformer | |
| Rated Capacity | 1.5~100kVA |
| Low-voltage Side Voltage | 400V |
| Low-voltage Side Current | 7.5~250A |
| High-voltage Side AC Output Voltage | 0~300kV |
| High-voltage Side AC Output Current | 0~3000mA |
| Measuring Turns Ratio | 1000:1 |
| Impedance Voltage | 4~9% |
| Output Voltage Waveform | Sine Wave |
| Turns Ratio Error | <±1% |
| Waveform Distortion Rate | >3% |
| Allowable Continuous Full-Load Operating Time | <1~2 hours (temperature rise 50ºC) |
| No-load Loss | 0.2%~0.4.0% |
| Voltage Measurement Accuracy | 1.0%FS±3 digits |
| Current Measurement Accuracy | 1.0%FS±3 digits |
| The parameters of the AC/DC dual-purpose test transformer are the same as in the table above. The rated DC voltage in the DC parameters is 1.4 times that of the AC, and the rated DC current is 0.7 times that of the AC current. | |
Other Recommended Specifications: