Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
  • Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
  • Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
  • Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
  • Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
Find Similar Products

Basic Info.

Output Current
5A, 4A, 3A, 2A, 1A, Optional
Degaussing Progress
0-100%
Power
Electronic
Customized Support
OEM, ODM, Obm, Software Reengineering
Input Type
Current Method
Minimum Resolution
0.10%
Transport Package
Carton or Wooden Case
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000

Product Description


Kdzd3000y Transformer Demagnetization Degaussing Function Equipment Demagnetization Tester
System Introduction

This instrument is a specialized equipment for eliminating residual magnetism in large power transformers. It plays an important role in protecting transformers from the impact of excitation inrush current, ensuring safe operation, and extending the service life of transformers.
During normal operation and testing, residual magnetism will be generated in the iron core of a large capacity transformer. When the capacity of the transformer is large, the harm of residual magnetism will also increase accordingly. Residual magnetism may cause misoperation of relay protection devices, resulting in the failure of transformer operation; At the same time, residual magnetism may also cause abnormal test results and affect the quality of electricity after transmission. Therefore, when abnormal phenomena or faults occur due to residual magnetism during the operation of transformers, they should be taken seriously. For this purpose, our company has developed a series of transformer demagnetization products. Our company is one of the earliest manufacturers in China to develop and produce demagnetization instruments, and has accumulated a wealth of practical experience.
 
The demagnetization instrument for power transformers is a new generation demagnetization instrument independently developed by our company. By adopting a reasonable composite current method technology, it is possible to quickly demagnetize power transformers and mutual inductors. For three-phase transformers, demagnetizing only one phase is sufficient, which is more time-saving and efficient.

 
Main technical indicators
input type
current method
output voltage
vpp-40v, which is automatically adjusted during the test
output current
5A, 4a, 3a, 2a, 1a, optional
degaussing progress
0-100%
minimum resolution
0.10%
power supply voltage
AC100V-240V ± 10%
frequency
50hz/60hz
working environment
- 10 ~ 50 ≤ 85% RH
 
Main technical features
The instrument adopts the composite current demagnetization method, and the current impact is small during the demagnetization process.
The demagnetization efficiency is high, and only one phase of the three-phase transformer can be demagnetized, greatly saving time.
The progress percentage and demagnetization progress indicator bar of the demagnetization process are intuitive and clear, and the demagnetization current curve graph is displayed.
The wiring is simple and can be directly demagnetized using the test line of the DC resistor.
Adopting digital current adjustment, the control accuracy of current is high.
Adopting a 5-inch color touch screen control makes it easier to operate.
The test results are automatically stored, recording demagnetization current data without the need for manual storage.
The report can be printed directly and stored on a USB drive.
High degree of intelligence, after setting the parameters, only one key is needed to complete the measurement work.
The software interface is simple and intuitive, with clear menus for storage, report export, printing, and more.
  
Main features of testing software
Adopting an embedded system, there is no risk of software poisoning.
Adopting a directory based storage method for test data, the management of test data is simple and convenient.
The testing system can directly print data.
Support USB data export function.
The software has a high degree of intelligence, and after the input and output signals are connected, only one key is needed to complete the measurement work.
The software interface is simple, intuitive, and practical.