AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set

Product Details
Customization: Available
Warranty: 1 Year
Rated Output Frequency: 30 ~ 300Hz
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
  • AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
  • AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
  • AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
  • AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
Find Similar Products

Basic Info.

Input Working Power Supply
Three-Phase 380V ± 10%, 50Hz
Equipment Model
300kw
Rated Output Power
300kw
Power
Electronic
Customized Support
OEM, ODM, Obm, Software Reengineering
Transport Package
Carton or Wooden Case
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000
Production Capacity
2500 Pieces

Product Description

 
Variable frequency power supply without partial discharge
 
platform
1 set
Rated counterweight
kW
lOOkw
output voltage
V
Single phase, 0~350V continuously adjustable
Output voltage waveform
 
sine wave
Frequency modulation range
Hz
20~30Hz
Frequency adjustment fineness
Hz
0.1Hz
Protection function
 
It has a variety of protection functions such as voltage, overcurrent, output bearing, high-voltage flashover, etc^
Field voltage regulator without partial discharge
quantity
set
1 set
Rated capacity
kVA
lOOkVA
output voltage
kV
High voltage side is double winding, each winding has 5kV, lOkV
 
2SkV output
Rated frequency
Hz
30~300Hz
Local discharge
pC
≤10pC
Running time
min
≤90min
No partial discharge compensation reactor
quantity
platform
2 sets
Rated voltage
kV
20kV
Rated current
A
5A
Inductance value
H
6H
Running time
min
≤90min
Other requirements
 
Can be used on vehicle
Capacitor voltage divider without partial discharge
A few li
set
1 set
Rated voltage
kV
60kV
Rated capacity
pF
300pF
Frequency of use
Hz
30~300Hz
measurement accuracy
 
Level 1.0
Other requirements
 
It has the function of partial discharge coupling; Equipped with special meter head, it can display the measured voltage peak
value, effective value, frequency, voltage waveform, etc
Digital partial discharge detector
quantity
set
 
Measurement channel
 
4 (completely independent)
Detection sensitivity
 
0.1pc
Weight measurement frequency band and cutoff frequency
 
3dB band: 10khz-1ookhz, can be combined in multiple gears;
The low end is divided into 10K, 20K, 40K and 80K;
High end is divided into 100k, 200K, 300K, 500K and 1000K;
Fundamental error of Q measurement in apparent discharge
 
Linearity error shall not be greater than ± (5% + 1pc);
Low repetition rate pulse response error shall not be greater than ± (5%+1PC); The asymmetry error of positive and negative
impulse response shall not be greater than ± (5% + 1pc)%
Pulse resolution time
 
Pulse resolution time is less than 100uS
synchronization
 
Meat can be delivered outside, and the same step outside: 30-300Hz automatic synchronization
AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
Environmental conditions for system use
1) Ambient temperature: - 10 ~ + 45
2) Maximum daily temperature difference: 25K
3) Relative humidity: ≤ 90%
4) Solar radiation intensity: 0.1w/cm ²
5) Altitude: ≤ 1000M
6) Place of use: Outdoor / indoor
7) There is no danger of fire and explosion.
8) There is no gas that corrodes metal and insulation.
9) Have a reliable grounding point.
10) The installation place shall be flat.


AC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test SetAC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test SetAC Hipot Tester Switchgear High Voltage Test Set Transformer Partial Discharge AC Dielectric Test Set
 