  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
  • Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Find Similar Products
  • Overview
  • Company Profile
  • Certifications
  • Product packaging
  • FAQ
Overview

Basic Info.

Model NO.
KDBR-N
Voltage Range
AC 1000V. Accuracy, ±0.2% (F.S) ±
Charger Power Supply Requirements
AC160V~265V
Transformer Capacity Test Range
6.3~125 000kVA
Built-in Power Supply Output Range
Voltage: 0~10V, Current: 0~10A
Current Range
AC 100A. Accuracy, ±0.2% (F.S) ±
Working Temperature
-20ºC~+60ºC
Power
Electronic
Customized Support
OEM, ODM, Obm, Software Reengineering
Trademark
KDZD
Origin
Hubei, China

Product Description

Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer

 

 
Product Overview
 
KDBR-N transformer capacity tester has the advantages of small size, simple operation and easy use. It has upgraded the internal processor, data acquisition system and national standard data, making the instrument more widely available and more accurate. KDBR-N transformer capacity tester includes functions such as transformer capacity, transformer no-load loss, transformer load loss and its code level determination, and electrical parameter measurement. The instrument has a high-efficiency rechargeable battery inside and can work without an external power supply. A fully charged battery can continuously measure more than 200 transformers. In addition, the instrument can provide a three-phase precision 50Hz sine wave AC test power supply. When measuring transformer capacity and transformer load loss, there is no need for an external three-phase test power supply and auxiliary equipment such as a voltage regulator and a current booster, thereby improving work efficiency. This product has many advantages such as small size, light weight, high measurement accuracy, good stability and simple operation. It can replace the previous method of measuring transformer loss and capacity using the multi-meter method. The wiring is simpler, and testing and recording are more convenient, which greatly improves your work efficiency.
 
 Built-in power supply output range
 
Voltage
0~10V
Current
0~10A
Characteristic channel test range and accuracy
2500m
Voltage range: AC 1000V. Accuracy, ±0.2% (F.S) ±1 word
no strong vibration, no strong electromagnetic field
Voltage range: AC 1000V. Accuracy, ±0.2% (F.S) ±1 word
 
Power and other indicators
 
measurement accuracy Power
±0.5% (F.S) (0.1≤CosΦ≤1) ±1.0% (F.S) (0.02≤CosΦ≤0.1)
Transformer capacity test range
6.3125 000kVA
Working temperature
-20+60
Charger power supply requirements
AC160V265V
Insulation
45Hz~65Hz
Insulation resistance of capacity test, voltage, and current input points to the housing ≥100MΩ
 
The charging power input withstands 2kV (effective value) of power frequency to the housing, and the test time is 1 minute
 
Host volume
32cm×24cm×13cm
Weight
4 (host)

Functional characteristics

1. Using ARM+FPGA+ADC mode and equipped with RT-Thread real-time operating system, the instrument system is more robust and has higher measurement accuracy.
2.7-inch color high-brightness LCD, icon-based touch interface, Chinese input, Chinese menu.
3. With complete electronic help, each operation has a wiring diagram and text description, and the operation is intuitive and simple.
4. Built-in large-capacity memory, which can store 1,000 sets of test data. USB port communication, on-site test data can be saved, and data can be uploaded to the PC according to customer needs.
5. Integrates mainstream wired (RS232) and wireless communication (Bluetooth, WIFI) functions to facilitate data upload and remote control.
6. With program remote upgrade function, the instrument program can be remotely upgraded according to customer requirements.
7. The real-time voltage channel and current channel waveform display can be observed in each test interface.
8. The voltage, current, frequency, power factor, active power, reactive power, and apparent power of the test circuit are displayed in real time through a single interface to facilitate the judgment of on-site wiring conditions.
9. The standard customized low-voltage short-circuit wire can firmly short-circuit the transformer terminal under test without screws and wrenches, which is convenient for on-site testing.
10. The capacity of various distribution transformers and power transformers can be measured on-site without the need for additional power supply, making the detection more convenient and faster
11. All test results are automatically corrected. You only need to enter relevant parameters (such as temperature, no-load correction coefficient, etc.), and the instrument can automatically perform various corrections such as waveform deformation correction, temperature correction, non-rated voltage correction, non-rated current correction, etc., to make the test results more accurate
12. In the transformer characteristic measurement, the maximum voltage range can reach 1000V, the maximum current range can reach 100A, and the internal protection circuit is equipped. The measurement accuracy can be guaranteed without switching the gear during measurement, and there is no need to worry about burning the instrument due to the wrong gear selection.
 
13. When testing the transformer characteristics, the voltage and current ranges can be flexibly and easily expanded, simply by connecting external voltage transformers and current transformers, which widens the test range of the instrument.
14. Based on the no-load and load losses in the test results, the performance level of three-phase oil-immersed distribution transformers and power transformers can be automatically estimated for on-site reference by staff.
 
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
 
Company Profile
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Certifications
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
Product packaging
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
FAQ
Transformer No-Load Characteristic Tester Empty Load Loss Tester Losses Test of Power Transformer
1. How is our product? 
    We are manufacturer, so preferential price and high quality can guarantee. 
 
2. How soon to get price?
     Usually provide within 6 hours once receiving inquiry. If you are very urgent, please call us then we will       do in priority. 
 
3. Whal is your terms of delivery?
     EXW,FOB, CFR, CIF, ect. Pls select your most conveient and cost effective. 
 
4. When there is difficulty in using ? 
     We will first provide equipment operation manual, operation video, or provide training through remote         video call. Ifnecessary, engineers will serve on door. 
 
5. What about the leading time for production? 
    That depends on order qty and product item. For normal items, usually within 3 working days. Delivery      time is determined by the logistics , generally is 5-7 days. 
 
6.How to send? 
    For most of our customers, we provide door-to-door service. You only to through import customs                clearance proceduresand pay the import tariff. 
 
7. How is packing and will the goods be damaged? 
     We will pack standard export packing for everyequipment, so far there is no damage yet, pls no worry.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier