Technical specifications
|
|
Source
|
Rechargeable lithium battery pack 9.6V, external charger
|
Battery level indicator
|
The battery symbol displays the battery level in 5 cells. When the battery level is too low, it will prompt to automatically shut down after 1 minute |
Power dissipation
|
Current consumption of 590mA, battery operates continuously for about 6 hours
|
Display mode
|
LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm
|
Instrument size
|
Length, width, and thickness: 240mm × 170mm × 68 mm
|
Jaw size
|
008B pointed small current clamp: 7.5mm × 13mm (optional)
040B circular current clamp: 35mm × 40mm (optional)
068B circular current clamp: 68mm × 68mm (optional)
300F flexible coil current sensor (with integrator): Φ 300mm (optional)
|
Number of channels
|
4-way voltage, 4-way current
|
Line voltage
|
1.0V~2000V
|
Phase voltage
|
1.0V~1000V
|
Current
|
008B current clamp 10mA~10.0A
040B current clamp 0.10A~100A
068B current clamp 1.0A~1000A
300F flexible coil current sensor (with integrator) 10A~3000A
|
Frequency
|
40Hz~70Hz
|
Electricity quantity parameters
|
W. VA, var, PF, DPF, cos φ, Tan φ
|
Electric energy parameters
|
Wh, varh, Vah
|
Harmonic
|
Yes, 0-50 times
|
Total harmonic distortion
|
Yes, 0-50 times, each phase
|
Expert mode
|
have
|
Number of transient recording groups
|
150 sets
|
Voltage flicker
|
have
|
Start current mode
|
Yes, 100 seconds
|
Three-phase imbalance
|
have
|
Record
|
300 days (recording 20 parameters simultaneously, recording 1 point every 5 seconds)
|
Min/Max Record Value
|
Yes, it can measure the maximum and minimum values over a period of time
|
Alarm
|
40 different types of parameter selection, 12800 sets of alarm logs
|
Peak value
|
have
|
Phasor diagram display
|
automatic
|
Screenshot capacity
|
60
|
Menu Language
|
English,Chinese
|
Communication interface
|
USB
|
Automatic shutdown
|
In alarm/trend chart recording/transient capture mode (waiting or in progress), the instrument does not automatically shut down.
In other testing modes, if there is no button operation within 15 minutes, it will automatically shut down after 1 minute of prompt.
|
Backlight function
|
Yes, suitable for use in the dark and at night
|
Instrument quality
|
Host: 1.6Kg (with battery)
008B pointed small current clamp: 170g × four
040B circular current clamp: 185g × four
068B circular current clamp: 530g × four
300F flexible coil current sensor (with integrator): 330g × four
Test cable and power adapter: 900g
Total weight: approximately 9.2Kg (including packaging)
|
Voltage test line length
|
3m
|
Current clamp wire length
|
2m
|
Working temperature and humidity
|
-10 ºC to 40 ºC; Below 80% Rh
|
Storage temperature and humidity
|
-10 ºC~60 ºC; Below 70% Rh
|
Input impedance
|
The input impedance of the test voltage is 1M Ω
|
Voltage resistance
|
The instrument circuit can withstand a sine wave AC voltage of 3700V/50Hz between the casing for 1 minute
|
Insulation
|
≥ 10M Ω between instrument circuit and protective casing
|
Structure
|
Double insulation, with insulated and vibration proof sheath
|
Suitable for safety regulations
|
IEC 61010 1000V Cat III/600V CAT IV, IEC61010-031, IEC61326, Pollution level 2
|
Random attachments
|
Host: 1 unit; Instrument package: 1 unit; Test lines: 5 (1 each in yellow, green, red, blue, and black); Crocodile clip: 5 pieces;Pen: 5; Charger: 1; Software CD: 1; Lithium battery pack: 1 unit; 2GB memory card: 1; Current sensor (optional).
|
Description of instrument accuracy (excluding current sensors)
|
|||
The data below are presented under benchmark conditions and on the basis of an ideal current transducer (fully linear and without phase shift).
|
|||
measurement
|
Measuring range
|
Display resolution
|
within the reference range Maximum error
|
frequency
|
35Hz~70Hz
|
0.01Hz
|
±(0.03)Hz
|
The true RMS value of the voltage
|
0.5V~1000V
|
The minimum resolution is 0.1V
|
±(0.5%+5dgt)
|
The true RMS value of the current
|
0.5mA~10A
|
The minimum resolution is 0.1mA
|
±(0.5%+5dgt)
|
Crest factor
|
1.00~3.99
|
0.01
|
±(1%+2dgt)
|
4.00~9.99
|
0.01
|
±(5%+2dgt)
|
|
Active power
|
0.001W~10000kW
|
Minimal resolution 0.001W
|
±(1%+3dgt) Cosφ≥0.8
|
±(1.5%+10dgt) 0.2≤Cosφ<0.8
|
|||
Reactive power Inductance&Capacitive
|
0.001VAR~9999.9kVAR
|
Minimal resolution 0.001VAR
|
±(1%+3dgt) Sinφ≥0.5
|
±(1.5%+10dgt) 0.2≤Sinφ<0.5
|
|||
Apparent power
|
0.000VA~10000kVA
|
The minimum resolution is 0.001VA
|
±(1%+3dgt)
|
Factor
|
-1.000~1.000
|
0.001
|
±(1.5%+3dgt) Cosφ≥0.5
|
±(1.5%+10dgt) 0.2≤Cosφ<0.5
|
|||
Active electrical energy
|
0.001Wh~10000MWh
|
Minimal resolution 0.001Wh
|
±(1%+3dgt) Cosφ≥0.8
|
±(1.5%+10dgt) 0.2≤Cosφ<0.8
|
|||
Reactive electrical energy Inductance&Capacitive
|
0.001VARh~10000MVARh
|
Minimal resolution 0.001VARh
|
±(1%+3dgt)Sinφ≥0.5
|
±(1.5%+10dgt)0.2≤Sinφ<0.5
|
|||
Apparent electrical energy
|
0.000VAh~9999.9MVAh
|
Minimal resolution 0.001VAh
|
±(1%+3dgt)
|
Phase angle
|
-180°~180°
|
1°
|
±(2°)
|
Tanφ(VA≥50VA)
|
-32.76~32.76
|
The minimum resolution is 0.001
|
φ:±(1°)
|
Displacement power factor(CFO)
|
-1.000~1.000
|
0.001
|
φ:±(1°)
|
Voltage harmonic ratio Contains 1~50 times(Vrms>50V)
|
0.0%~99.9%
|
0.1%
|
(1~20 times)±(1%+5dgt)(21~30 times)±(1%+10dgt) (31~50 times)±(1%+15dgt) |
Voltage harmonic angle(Vrms>50V)
|
-179°~180°
|
1°
|
± (3 °) harmonics 1-25 times
|
± (10 °) harmonics 26-50 times
|
|||
Current harmonic ratio Contains 1~65 times(Arms>I range÷100).
|
0.0%~99.9%
|
0.1%
|
(1-20 times) ± (1%+5dgt) (21-30 times) ± (1%+10dgt) (31-50 times) ± (1%+15dgt)
|
Current harmonic angle(Arms>I range÷100).
|
-179°~180°
|
1°
|
± (3 °) harmonics 1-25 times ± (10 °) harmonics 26-50 times
|
Total harmonic rate(THD or THD-F)≤50
|
0.0%~99.9%
|
0.1%
|
±(1%+10dgt)
|
Distortion factor (DF or THD-R) ≤ 50 |
0.0%~99.9%
|
0.1%
|
±(1%+10dgt)
|
Transformer K-factor
|
1.00~99.99
|
0.01
|
±(5%)
|
Three-phase imbalance
|
0.0%~100%
|
0.1%
|
±(1%)
|
Current sensor characteristics
|
|||
Current sensor model
|
True effective value of current
|
Maximum error of true effective value of current
|
phase angle φ maximum error
|
008B CT size: F8mm
|
10mA~99mA
|
±(1 % + 3dgt)
|
±(1.5°),Arms≥20mA
|
00mA~10.0A
|
±(1 % + 3dgt)
|
±(1°)
|
|
040B CT size: F40mm
|
0.10A~0.99A
|
±(1 % + 3dgt)
|
±(1.5°)
|
1.00A~100A
|
±(1 % + 3dgt)
|
±(1°)
|
|
068B CT size: F68mm
|
1.0A~9.9A
|
±(2 % + 3dgt)
|
±(3°)
|
10.0A~1000A
|
±(2 % + 3dgt)
|
±(2°)
|
|
300F CT size: F300mm
|
10A~99A
|
±(1 % + 3dgt)
|
±(3°)
|
100A~3000A
|
±(1 % + 3dgt)
|
±(2°)
|