Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
  • Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
KDRB-X
Type
Electric Testing Machine
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Weight
26kg
Power Source
AC110V/220V/380V
Product Name
Transformer Winding Deformation Tester
Detection Method
Frequency Response Method and Impedance Method
Scanning Method
Linear Scanning, Segmented Frequency Sweep Measure
Amplitude Measurement Range
-120dB - +20dB
Amplitude Measurement Accuracy
0.1dB
Scanning Frequency Accuracy
0.01%
Signal Input Impedance
1mΩ
Signal Output Impedance
50Ω
Signal Output Amplitude
±20V
in-Phase Test Repetition Rate
99.9%
Transport Package
Wooden Box
Specification
50*28*50cm
Trademark
KDZD
Origin
Hubei, China
HS Code
9030841000
Production Capacity
2500 Pieces

Packaging & Delivery

Package Size
50.00cm * 28.00cm * 50.00cm
Package Gross Weight
26.000kg

Product Description

Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer

Feature of KDRB-X Transformer Winding Deformation Tester:

1.The acquisition control uses a high-speed, highly integrated microprocessor.
2.This instrument comes with an industrial computer for independent use, without a laptop, and can also be connected to a laptop through a USB interface.
3.The instrument automatically analyzes and judges the test results and generates electronic documents (Word) for storage and printing.
4.The instrument also meets the technical requirements of the power standard DL/T911-2016 "Frequency Response Analysis Method for Power Transformer Winding Deformation" and DL/T1093-2008 "Guidelines for Detection and Judgment of Power Transformer Winding Deformation by Reactance Method".
5.High-speed dual-channel 16-bit A/D sampling (the waveform curve changes significantly when the tap switch is changed in the field test).
6.The frequency response method hardware movement uses DDS dedicated digital high-speed sweep frequency technology (USA). Through testing, it can accurately diagnose winding distortion, bulging, displacement, tilt, turn-to-turn short-circuit deformation and phase-to-phase contact short-circuit and other faults.
7.The frequency response method has the dual measurement system functions of linear sweep frequency measurement and segmented sweep frequency measurement, and is compatible with the measurement modes of the two current domestic technical schools.
8.The amplitude-frequency characteristics of the frequency response method meet the national technical indicators for amplitude-frequency characteristic testers. The horizontal axis (frequency) has two types of linear and logarithmic divisions, so the printed curve can be a linear division curve or a logarithmic division curve, and the user can choose according to actual needs.
9.The impedance method adopts a three-phase wiring single-phase measurement method. It only needs to short-circuit the low-voltage side and connect the three phases on the high-voltage side at one time. The short-circuit impedance of each phase can be calculated by automatic measurement at one time.
10.The impedance method can synchronously measure voltage, current, and frequency, and display the real-time waveform of the test.
11. The impedance method can use the internal power supply or an external power supply.
Product Parameters
KDRB-X Transformer Winding Deformation Tester
1. Sweep frequency response method
Scanning method
 
Linear scanning distribution:
Sweep frequency measurement range: (10Hz)-(10MHz) 40000
sweep frequency points, resolution of 0.25kHz, 0.5kHz and 1kHz.
Segmented frequency sweep measurement distribution:
Frequency sweep measurement range: (0.5kHz)-(1MHz), 2000 sweep points; 
(0.5kHz)-(10kHz) 
(10kHz)-(100kHz) 
(100kHz)-(500kHz)
(500kHz)-(1000kHz)
Other technical parameters
 
Amplitude measurement range
-120dB - +20dB
Amplitude measurement accuracy 0.1 dB
Sweep frequency accuracy 0.01%
Signal input impedance
1MΩ
Signal output impedance
50Ω
Signal output amplitude
±20V
In-phase test repetition rate 99.9%
2. Impedance method
Measurement accuracy Voltage: 0.2% Current: 0.2%
Impedance range 0~100%
Voltage measurement range AC 25V~500V
Current measurement range AC 0.1A~10A
Working humidity 0~80%
In-phase test repetition rate 99.9%
 
Product Description

 

Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion AnalyzerWinding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion AnalyzerWinding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer
Company Profile

Winding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion AnalyzerWinding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion AnalyzerWinding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion AnalyzerWinding Deformation Tester 2 in 1 Sfra Impedance Transformer Coil Distortion Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier