Hvhipot Electric Power Quality Analyzer Portable Power Tester

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year, 1 Year
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
  • Hvhipot Electric Power Quality Analyzer Portable Power Tester
Find Similar Products

Basic Info.

Model NO.
KDZD5000
After-Sales Service
Yes
Phase Voltage
1.0V~1000V
Operating Temperature
-10 ºC to 40 ºC; Below 80% Rh
Harmonics
Yes, 0-50 Times
Measuring Energy Range
1.0V~2000V; 1.0V~1000V
Phase
Three Phase
Number of Transient Recording Groups
150 Groups
Electric Energy Parameters
Wh, Varh, Vah
Dimensions
240mm*170mm*68mm
Voltage Flicker
Yes
Total Harmonic Distortion
Yes, 0-50 Times, Each Phase
Display Type
Digital Only
Frequency
40Hz~70Hz
Line Voltage
1.0V~2000V
Number of Channels
4 Voltage and 4 Current Channels
Expert Mode
Yes
Transport Package
Wooden Box with Foam Inside
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000
Production Capacity
80 Set/Sets Per Month

Product Description

Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester
 
 
 
Technical specifications
Source
Rechargeable lithium battery pack 9.6V, external charger
Battery level indicator
The battery symbol displays the battery level in 5 cells. When the battery level is too low, it will prompt to automatically shut
down after 1 minute
Power dissipation
Current consumption of 590mA, battery operates continuously for about 6 hours
Display mode
LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm
Instrument size
Length, width, and thickness: 240mm × 170mm × 68 mm
Jaw size
008B pointed small current clamp: 7.5mm × 13mm (optional) 
040B circular current clamp: 35mm × 40mm (optional) 
068B circular current clamp: 68mm × 68mm (optional) 
300F flexible coil current sensor (with integrator): Φ 300mm (optional)
Number of channels
4-way voltage, 4-way current
Line voltage
1.0V~2000V
Phase voltage
1.0V~1000V
Current
008B current clamp 10mA~10.0A
040B current clamp 0.10A~100A 
068B current clamp 1.0A~1000A 
300F flexible coil current sensor (with integrator) 10A~3000A
Frequency
40Hz~70Hz
Electricity quantity parameters
W. VA, var, PF, DPF, cos φ, Tan φ
Electric energy parameters
Wh, varh, Vah
Harmonic
Yes, 0-50 times
Total harmonic distortion
Yes, 0-50 times, each phase
Expert mode
have
Number of transient recording groups
150 sets
Voltage flicker
have
Start current mode
Yes, 100 seconds
Three-phase imbalance
have
Record
300 days (recording 20 parameters simultaneously, recording 1 point every 5 seconds)
Min/Max Record Value
Yes, it can measure the maximum and minimum values over a period of time
Alarm
40 different types of parameter selection, 12800 sets of alarm logs
Peak value
have
Phasor diagram display
automatic
Screenshot capacity
60
Menu Language
English,Chinese
Communication interface
USB
Automatic shutdown
In alarm/trend chart recording/transient capture mode (waiting or in  progress), the instrument does not automatically shut down.
 
In other testing modes, if there is no button operation within 15 minutes, it will automatically shut down after 1 minute of prompt.
Backlight function
Yes, suitable for use in the dark and at night
Instrument quality
Host: 1.6Kg (with battery) 
008B pointed small current clamp: 170g × four 
040B circular current clamp: 185g × four 
068B circular current clamp: 530g × four 
300F flexible coil current sensor (with integrator): 330g × four 
Test cable and power adapter: 900g
Total weight: approximately 9.2Kg (including packaging)
Voltage test line length
3m
Current clamp wire length
2m
Working temperature and humidity
-10 ºC to 40 ºC; Below 80% Rh
Storage temperature and humidity
-10 ºC~60 ºC; Below 70% Rh
Input impedance
The input impedance of the test voltage is 1M Ω
Voltage resistance
The instrument circuit can withstand a sine wave AC voltage of  3700V/50Hz between the casing for 1 minute
Insulation
≥ 10M Ω between instrument circuit and protective casing
Structure
Double insulation, with insulated and vibration proof sheath
Suitable for safety regulations
IEC 61010 1000V Cat III/600V CAT IV, IEC61010-031, IEC61326, Pollution level 2
Random attachments
Host: 1 unit; Instrument package: 1 unit; Test lines: 5 (1 each in yellow, green, red, blue, and black); Crocodile clip: 5 pieces;Pen: 5; Charger: 1; Software CD: 1; Lithium battery pack: 1 unit; 2GB memory card: 1; Current sensor (optional).
 Description of instrument accuracy (excluding current sensors)
 The data below are presented under benchmark conditions and on the basis of an ideal current transducer (fully linear and without phase shift).
measurement
Measuring range
Display resolution
 within the reference range Maximum error
frequency
35Hz~70Hz
0.01Hz
±(0.03)Hz
The true RMS value of the voltage
0.5V~1000V
The minimum resolution is 0.1V
±(0.5%+5dgt)
The true RMS value of the current
0.5mA~10A
The minimum resolution is 0.1mA
±(0.5%+5dgt)
Crest factor
1.00~3.99
0.01
±(1%+2dgt)
4.00~9.99
0.01
±(5%+2dgt)
Active power
0.001W~10000kW
 Minimal resolution 0.001W
±(1%+3dgt) Cosφ≥0.8
±(1.5%+10dgt) 0.2≤Cosφ<0.8
Reactive power Inductance&Capacitive
0.001VAR~9999.9kVAR
Minimal resolution 0.001VAR
±(1%+3dgt) Sinφ≥0.5
±(1.5%+10dgt) 0.2≤Sinφ<0.5
Apparent power
0.000VA~10000kVA
The minimum resolution is 0.001VA
±(1%+3dgt)
Factor
-1.000~1.000
0.001
±(1.5%+3dgt) Cosφ≥0.5
±(1.5%+10dgt) 0.2≤Cosφ<0.5
Active electrical energy
0.001Wh~10000MWh
Minimal resolution 0.001Wh
±(1%+3dgt) Cosφ≥0.8
±(1.5%+10dgt) 0.2≤Cosφ<0.8
Reactive electrical energy Inductance&Capacitive
0.001VARh~10000MVARh
Minimal resolution 0.001VARh
±(1%+3dgt)Sinφ≥0.5
±(1.5%+10dgt)0.2≤Sinφ<0.5
Apparent electrical energy
0.000VAh~9999.9MVAh
Minimal resolution 0.001VAh
±(1%+3dgt)
Phase angle
-180°~180°
±(2°)
Tanφ(VA≥50VA)
-32.76~32.76
The minimum resolution is 0.001
φ:±(1°)
Displacement power factor(CFO)
-1.000~1.000
0.001
φ:±(1°)
Voltage harmonic ratio Contains 1~50 times(Vrms>50V)
0.0%~99.9%
0.1%
 (1~20 times)±(1%+5dgt)(21~30 times)±(1%+10dgt)
(31~50 times)±(1%+15dgt)
Voltage harmonic angle(Vrms>50V)
-179°~180°
± (3 °) harmonics 1-25 times
± (10 °) harmonics 26-50 times
Current harmonic ratio Contains 1~65 times(Arms>I range÷100).
0.0%~99.9%
0.1%
(1-20 times) ± (1%+5dgt) (21-30 times) ± (1%+10dgt) (31-50 times) ± (1%+15dgt)
Current harmonic angle(Arms>I range÷100).
-179°~180°
± (3 °) harmonics 1-25 times ± (10 °) harmonics 26-50 times
Total harmonic rate(THD or THD-F)≤50
0.0%~99.9%
0.1%
±(1%+10dgt)
Distortion factor
(DF or THD-R) ≤ 50
0.0%~99.9%
0.1%
±(1%+10dgt)
Transformer K-factor
1.00~99.99
0.01
±(5%)
Three-phase imbalance
0.0%~100%
0.1%
±(1%)
Current sensor characteristics
Current sensor model
True effective value of current
Maximum error of true effective value of current
phase angle φ maximum error
008B CT size: F8mm
10mA~99mA
±(1 % + 3dgt)
±(1.5°),Arms≥20mA
00mA~10.0A
±(1 % + 3dgt)
±(1°)
040B CT size: F40mm
0.10A~0.99A
±(1 % + 3dgt)
±(1.5°)
1.00A~100A
±(1 % + 3dgt)
±(1°)
068B CT size: F68mm
1.0A~9.9A
±(2 % + 3dgt)
±(3°)
10.0A~1000A
±(2 % + 3dgt)
±(2°)
300F CT size: F300mm
10A~99A
±(1 % + 3dgt)
±(3°)
100A~3000A
±(1 % + 3dgt)
±(2°)


KDZD5000 Basic Function Introduction:

Test function: Real time waveform display (4 voltage/4 current channels); True effective values of voltage and current; Voltage DC component; Peak current and voltage; The maximum/minimum values of current and voltage over a period of time; Phasor diagram display; Measurement of harmonics in each phase, up to 50 harmonics; The bar chart displays the harmonic ratio of each phase current and voltage; Calculation of Total Harmonic Distortion (THD); The active/reactive/apparent power values and total values of each phase; The active/reactive/apparent electrical energy values and total values of each phase; Transformer K-factor calculation; COS φ Calculation of displacement power factor (DPF) and power factor (PF); Flash calculation; Calculation of three-phase imbalance (voltage and current)

Capture and monitoring functions: It can capture and detect instantaneous changes in the voltage and current parameters of the power grid, including voltage and current fluctuations, voltage and current surges, drops, short-term interruptions, transient overvoltage, surg
e current, and instantaneous distortion of current and voltage. The instrument can store up to 150 sets of transient waveforms simultaneously.


Start current monitoring: It can monitor the surge current of the circuit and the starting current of electrical equipment during startup, which helps to design the installed capacity correctly. It can display the rise/fall curve of the effective value during the startup process, the envelope curve of the startup current, and the waveforms of four currents and four voltages. After triggering, it can record for about 100 seconds, storing all instantaneous current and voltage values and waveform curves for each cycle within 100 seconds.

Record storage function: All testing parameters for basic testing functions (Urms, Uthd, Ucm, Uub, Hz, Vrms, Vthd, Vcm, Vub, PST, Arms, Athd, Acf, Aunb, KF, W, VAR, VA, PF, COS) can be tested φ, TAN φ), Record 123 parameters of voltage 50th harmonic and current 50th harmonic, and generate trend curves. Long term data recording can be performed as needed. (Selecting 20 parameters at the same time and recording them every 5 seconds can record for approximately 300 days.)

Alarm function: The selected parameters can be set with limit values as needed to monitor whether they exceed the limit. When they exceed the limit, an alarm log will be generated, such as voltage overvoltage, current overcurrent, imbalance exceeding the limit, a certain harmonic ratio exceeding the limit, frequency exceeding the limit, active power exceeding the limit, total harmonic distortion exceeding the limit, etc. Up to 40 sets of alarm monitoring parameters can be set, and each set can set different monitoring parameters (including 123 different parameters for 50 harmonics) and limit values, The shortest time for exceeding the limit can be set. Up to 12800 sets of alarm log records can be stored.

Screenshot function: On the testing page, you can take a screenshot and store the current screen image, while automatically saving the recorded time and the testing mode. Such as saving current and voltage waves, harmonic bar charts, phasor diagrams, etc. Up to 60 sets of screenshots can be saved simultaneously.

Communication function: By communicating with the computer via USB, the monitoring software can display real-time waveforms of power quality analysis tests, and can read transient waveforms, trend chart records, alarm lists, test screenshots, etc. detected and captured.
Setting functions: Users can set the time and date, set the contrast and brightness of the display screen, and set the corresponding colors of each phase line in the instrument; Can set the wiring method and power grid type of the instrument; Different current clamps and voltage test ratios can be selected; You can choose between Chinese or English menus.

Chinese/English Help Menu: At each stage of the operation, you can press the "Help" button at any time to obtain relevant help information.

Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester
Hvhipot Electric Power Quality Analyzer Portable Power Tester

Hvhipot Electric Power Quality Analyzer Portable Power TesterHvhipot Electric Power Quality Analyzer Portable Power TesterHvhipot Electric Power Quality Analyzer Portable Power Tester
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier