Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
  • Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
Find Similar Products

Basic Info.

Model NO.
KDZD
Configuration
Capacitive Touch Screen, Automatic Storage,etc
Product Name
Ultra Low Frequency High Voltage Generator
Voltage Waveform Distortion
≤ 5%
Voltage Positive and Negative Peak Error
≤ 3%
Output Frequency
0.1Hz, 0.05Hz, 0.02Hz
Customized Support
OEM, ODM, Obm, Software Reengineering
Protection Time
≤ 10ms
Rated Voltage
30kv, 40kv, 50kv, 60kv, 80kv, 90kv, etc
Measurement Accuracy
3%
Protection
Overvoltage Protection, etc
Power
Electronic
Transport Package
Wooden Case
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000
Production Capacity
2500 Pieces

Product Description


Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
Product parameters
Product Name
Ultra Low Frequency High Voltage Generator
Rated voltage
30kV, 40kV, 50kV, 60kV, 80kV, 90kV, etc
Measurement accuracy
3%
Voltage waveform distortion
 ≤ 5%
Voltage positive and negative peak error
 ≤ 3%
Output frequency
0.1Hz, 0.05Hz, 0.02Hz

Product Features

★Current, voltage, and waveform data are directly obtained through high-voltage side sampling, so the data is true and accurate
Overvoltage protection: When the output exceeds the set voltage limit, the instrument will shut down for protection, with an action time of less than 20 milliseconds
Overcurrent protection: designed as a dual protection of high and low voltage, the high voltage side can be precisely shut down for protection according to the set value; When the current on the low-voltage side exceeds the rated current, shutdown protection will be implemented
★The high-voltage output protection resistor is designed inside the boost, so there is no need to connect another protection resistor externally
★For products with a voltage of over 50kv, the series combination method can achieve multiple uses for one machine, making it extremely convenient to use
★Due to the use of high and low voltage closed-loop negative feedback control circuit, there is no capacitance rise effect in the output
★Measurement accuracy: 2%                                   
★Voltage positive and negative peak error: ≤ 3%
★Voltage waveform distortion: ≤ 5%                      
★Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
★Power supply: AC 50Hz, 220V ± 5% (generator: AC 50Hz, 220V ± 5%)
★Test time: Handover: 60 minutes     
★Prevention: 5 minutes (can run for a long time)
 
Model no Output
Voltage/
Current
(Peak)
Load Capacity Control Unit Booster(Tank) Power 
Capacitance/
Freuency
Net Dim.
(cm)
Net Wt
 (kg)
Net Dim.
(cm)
Net Wt
(kg)
KDVLF-40  40kV/20mA 0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20   6 29x15×35 25 1200W
KDVLF-50  50kV/20mA 0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20   6 29x15×35 25 1500W
KDVLF-60  60kV/59mA 0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 60kV;
40×31×20   6 45×19×36 45 2000W
KDVLF-80  80kV/59mA 0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 80kV;
Capacity:10µF for single booster (40/40kV)
40×31×20   6 29x15×35     25 3000W
36x19×45     45
KDVLF-90  90kV/59mA 0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 90kV;
Capacity:10µF for single
booster (40/50kV)

40×31×20
 
  6 29x15×35     25 3500W
36x19×45     45
                                         
Function comparison of VLF series models
 
Output
(Peak)
Structure Model no AC Withstand Voltage Test Tan Delta Test PD Test Capacity
(μF)
Insulation
Resistance
Test (IR)


30KV

1*Controller
1*30KV Booster
1*Capacitor
KDVLF-30 X X X X
KDVLF-30A X
KDVLF-30B X X
KDVLF-30C


40KV

1*Controller
1*40KV Booster
1*Capacitor
KDVLF-40 X X X X
KDVLF-40A X
KDVLF-40B X X
KDVLF-40C


50KV

1*Controller
1*50KV Booster
1*Capacitor
KDVLF-50 X X X X
KDVLF-50A X
KDVLF-50B X X
KDVLF-50C

60KV
1*Controller
1*60KV Booster
1*Capacitor
KDVLF-60 X X X X
KDVLF-60A X
KDVLF-60B X X
KDVLF-60C

70KV
1*Controller
1*30KV Booster
1*40KV Booster
1*Capacitor
KDVLF-70 X X X X
KDVLF-70A X X


80KV
1*Controller
1*30KV Booster
1*50KV Booster
1*Capacitor, or

1*Controller
2*40KV Booster
1*Capacitor
KDVLF-80 X X X X
KDVLF-80A X
KDVLF-80B X X
KDVLF-80C


90KV

1*Controller
1*40KV Booster
1*50KV Booster
1*Capacitor
KDVLF-90 X X X X
KDVLF-90A X
KDVLF-90B X X
KDVLF-90C
Note:  DC leakage current measurement for buyer's option (any type can add this function if required).
Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester
Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester

Kdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot TesterKdzd Electric Vlf Very Low Frequency AC Hipot Tester 0.1Hz Cable AC Withstand Voltage Tester 30kv Vlf Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier