Customization: | Available |
---|---|
Warranty: | 1 Year |
Alarm Delay: | 2s |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameter
|
|
|
DC voltage: ≥ 20kV (1.0-20.0kV);
Setting resolution 0.1kV
Shock wave front time: 1.2 μ S ± 30%;
Half time after wave: 50 μ S ±20%;
|
|
|
Peak voltage
|
Low: 1kV~4.991kV ± 3%;
High: 5kV~19.991kV ± 3%;
|
|
Impact time interval: 5-99 (S)
Setting resolution for 1s
Alarm delay of 2s
Number of pressurizations: 1 to 9999 impacts
|
|
|
Control and display functions: DC charging voltage, charging time timing, and the switching status of the main power contactor
|
|
|
Polarity: positive and negative; Instrument internal resistance: 500 Ω
|
|
|
Rated voltage of working power supply:~220V ± 10% 50Hz
|
|
|
Power consumption: 50VA
|
|