Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Still deciding? Get samples of US$ 1450/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (25)
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
  • Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Selling Units
Single Item
Accessories
High-Voltage Power Supply Connecting Line
Single Gross Weight
8.000kg
Withstand Voltage
100kv
Power
250W
Single Package Size
34X23X12.Cm
Customized Support
OEM,ODM,Obm,Software Reengineering
Partial Discharge
80kv
Trademark
KDZD
Origin
Hubei, China
HS Code
9030332000

Product Description

Product Description
Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price
Ground Resistance Measuring Instrument Digital Clamp Type Earth Resistance Tester Price

Products introduction

KD50A series digital insulation resistance tester, also known as megohmmeter and high-voltage insulation resistance meter, is used for insulation resistance test. This instrument has the functions of large-screen LCD gray backlight display, data storage, data query, alarm, automatic discharge, charging, automatic shutdown, etc. At the same time, it also has the function of measuring DC voltage AC voltage absorption ratio and polarization index. The whole machine is beautiful, with wide range, high resolution, convenient operation, convenient carrying, accurate, reliable, stable performance, large output power and strong anti-interference ability. KD50A series digital insulation resistance tester also has shock-proof, dust-proof and moisture-proof structure and can adapt to harsh working environment. It is a commonly used instrument for telecommunication, electric power, meteorology, computer room, oil field, electromechanical installation and maintenance, and industrial enterprise departments that use electric power as industrial power or energy. It is suitable for measuring the insulation resistance of various insulation materials and transformers, motors, cables and electrical equipment. KD50A series digital insulation resistance tester consists of medium and large scale integrated circuits. This meter has large output power and multiple output voltage levels (6 voltage levels). The rated insulation test voltage range is 100V~15kV (the output voltage is determined according to the model), and the step adjustment voltage function can output a variety of different voltage levels (for example, the 15kV model can produce 12KV and other voltage levels, with a wider range of use), and the insulation resistance measurement range is 0.01M Ω~50T Ω (the measurement range is determined according to the model); DC voltage measurement range 0~1000V; AC voltage measurement range 0~750V; DC current measurement range: 0.01nA-6mA; Capacitance measurement range: 10nF~50uF.

 

 
Main technical features
Function: insulation resistance test, voltage test, current test, capacitance test Reference condition: 23 ± 5 , below 75% rh Rated applied voltage (V): 100V 250V 500V 1000V 2500V 5000V precision rated voltage × 1±10% 250V 500V 1000V 2500V 5000V 10KV precision rated voltage × 1±10% 500V 1000V 2500V 5000V 10KV 15KV precision rated voltage × 1±10% Insulation resistance range (G Ω): 0.01M Ω 10T Ω Accuracy: ± 3% rdg ± 5dgt Resolution: 0.01M Ω : 0.01M Ω 35T Ω Accuracy: ± 3% rdg ± 5dgt Resolution: 0.01M Ω : 0.01M Ω 50T Ω Accuracy: ± 3% rdg ± 5dgt Resolution: 0.01M Ω DC voltage range: 0.1~1000V Accuracy: ± 1.5% rdg ± 3dgt Resolution: 0.1V AC voltage range: 0.1~750V Accuracy: ± 1.5% rdg ± 3dgt Resolution: 0.1V DC current measurement: 0.01nA 6mA Accuracy: ± 5.0% rdg ± 5dgt Resolution: 0.01nA Capacitance measurement: 10nF 50uF Accuracy: ± 10% rdg ± 5dg (resolution: 10nF) Output short-circuit current: ≥ 6mA Measurement of absorption ratio and polarization index: yes Power supply: 12V rechargeable battery Backlight: controllable gray white screen backlight, suitable for use in the dark field Display mode: 4-bit large LCD display, gray and white screen backlight LCD display size: 108mm × 65mm Instrument size: 240mm (length) × 188mm (width) × 85mm high USB interface: with USB interface, software monitoring, storage data can be uploaded to the computer, save and print Communication cable: 1 USB communication cable Test line: high voltage bar red 3m, high voltage test line black 1.5m, green line 1.5m Data storage: 500 groups, flashing "FULL" symbol indicates that the storage is full Data lookup: data lookup function: "READ" symbol display Overflow display: Overrange overflow function: "OL" symbol display Alarm function: send alarm prompt when the measured value exceeds the alarm setting value power waste: Standby: 30mA Max (backlight off) Turn on backlight: 42mA Max Measurement: 200mA Max (backlight off) Instrument mass: 2340g (including battery) Battery voltage: the battery voltage is insufficient, and the low power symbol "" is displayed Automatic shutdown: the instrument will be shut down after about 15 minutes without operation Insulation resistance: ≥ 50M Ω (between measuring line and shell) Withstand voltage: AC3kV/50Hz 1min Operating temperature and humidity: - 10 ~+50 85% RH Storage temperature and humidity: - 15 ~+55 90% RH Applicable safety regulations: IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529 (IP54), pollution, etc. 2, CAT 300V Packing list Instrument: 1 set High pressure rod: 1 red High voltage test line: 2 (1 black, 1 green) Monitoring software CD: 1 copy USB communication cable: 1 Charger: 1 Instructions and warranty certificate: 1 set Instrument box: 1

 